In-field Flowlines, Steel Catenary Risers and Export Pipelines
The exposure to dropped objects, the riser fatigue, the installation strategies,
    the repair and maintenance plan and the low ambient water temperature
    effect
The yield minimum stresses at the hang-off point and sag-bend area,
    the VIV performance
The global dynamic analysis to confirm no interference with the hull,
    other risers, mooring lines and other parts of the structure
The wall thickness to resist internal and external pressure, collapse,
    hydrotest, buckle propagation, temperature and fatigue requirement